BQTPQ - METALCLAD CERAMALLOY CP PLUS BASE
- MSDS: BQTPQ
- Manufacturer: PALMER INTERNATIONAL INC
- Product Name: METALCLAD CERAMALLOY CP PLUS BASE
- National Stock Number: 8040-00N036976
Product Identification
Product ID:METALCLAD CERAMALLOY CP PLUS BASE
MSDS Date:12/01/1991
FSC:8040
NIIN:00N036976
MSDS Number: BQTPQ
Responsible Party
US
Emergency Phone: 215-584-4241
Info Phone: 215-584-4241
Cage: 00933
Contractor
Telephone: 610-584-4241
Cage: 00933
Ingredients
<0.1.
CAS: 25068-38-6
RTECS: KC2100000
Fraction By Weight: 20-25%
EPOXIDIZED PHENOL-FORMALDEHYDE NOVOLAC;(EPOXY PHENOL
CAS: 28064-14-4
Fraction By Weight: <5%
SILANE, 3-(2,3-EPOXY PROPOXY)
CAS: 2530-83-8
RTECS: VV4025000
Fraction By Weight: <1%
SILICA; (COLLOIDAL SILICA)
CAS: 67762-90-7
Fraction By Weight: <2%
OSHA PEL 20 MPPCF (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
ZIRCONIUM OXIDE
CAS: 1314-23-4
RTECS: ZH8800000
Fraction By Weight: 70-75%
OSHA PEL 5 MG/M3;10 STEL (ZR)
ACGIH TLV: 5 MG/M3;10 STEL (ZR)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:CAN CAUSE IRRITATION.
SKIN:PROLONGED OR REPEATED CONTACT CAN CAUSE MODERATE IRRITATION,
DERMATITIS. BREATHING:NORMALLY NO PROBLEM UNLESS HEATED.
INGEST:SLIGHT TOXIC.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH W/LG AMTS OF WATER LIFTING EYELIDS OCCASION:GET
PROMPT MD ATTN.SKIN:WASH THORO W/SOAP & WATER, REMOVE CONTAM CLTHG
PROMPTLY; WASH CLTHG BEFORE REUSE.INGEST:DO NOT INDUCE VOM!KEEP
PERSON WAR M, QUIET & GET MD ATTN.ASPIR OF MATL INTO LUNGS DUE TO
VOM CAN CAUSE CHEM PNEUMONITIS WHICH CAN BE FATAL.INHAL:MOVE
AFFECTED PERSON TO FRESH AIR.IF BRTHG IF DFCLT, ADMIN OXYGEN. IF
BRTHG (SUPP DATA)
Fire Fighting
Flash Point:>400F,>204C
Extinguishing Media:CARBON DIOXIDE-DRY CHEMICAL-FOAM-WATER FOG. USE
WATER FOR COOLING MATERIAL STORED IN VICINITY OF FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:SMALL SPILL:SCRAPE UP/SOAK UP WITH ABSORBENT
MATERIAL. LARGE SPILL:SCRAPE UP/SOAK UP WITH ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:IF TLV OF PROD IS EXCEEDED, NIOSH/MSHA JOINTLY
APPRVD AIR SUPPLY RESP IS ADVISED IN ABSENCE OF PROPER
ENVIRONMENTAL CONTROL.OSHA REGS ALSO PERMIT OTHER NIOSH/MSHA RESP
UNDER SPECIFIED CNDNTNS.(SEE YOU R SAFETY EQUIP SUPPLIER). (SUPP
DATA)
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL AND/OR LOCAL
EXHAUST) VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:RESISTANT GLOVES (NITRILE RUBBER).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH; SAFETY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID:HAS STOPPED, GIVE ARTIFICIAL RESPIRATION. KEEP PERSON WARM,
QUIET, AND GET MEDICAL ATTENTION. RESP PROT:ENGINEERING OR
ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOSURE.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>392F,>200C
Vapor Pres:SEE ING
Vapor Density:NON VOL
Spec Gravity:2.75
Evaporation Rate & Reference:NON VOLATILE
Appearance and Odor:GRAY PASTE.
Percent Volatiles by Volume:0%
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZERS, ACIDS, AMINES AND BASES.
Stability Condition to Avoid:KEEP AWAY FROM HEAT AND OPEN FLAME.
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE AND DIOXIDE,
VARIOUS HYDROCARBONS, ETC.
Disposal
Waste Disposal Methods:SMALL SPILLS:INCINERATE OR LANDFILL IN
ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS. LARGE
SPILL:INCINERATE OR LANDFILL IN ACCORDANCE WITH ALL FEDERAL, STATE,
AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.